  https://www.phoenixcontact.com/us/products/0900838 08/01/2016???page? 1 ?/? 5 electronic device circuit breaker?-?ecp-e2-8a?-?0900838 please be informed that the data shown in this pdf document is generated from our online catalog. please find the complete data in the user's documentation. our general terms of use for downloads are valid (http://phoenixcontact.com/download) electronic device circuit breaker, number of positions:?1, connection method:?screw connection, width:?12.5 mm, fuse type:?electronic, fuse type:?automatic device, mounting type:?on base element, color:?black why buy this product includes the advantages of current limitation sufficient supply of all error-free load circuits output voltage of switched-mode power supply unit remains stable responds faster than switched-mode power supply unit to overload and short circuit application - all aspects of the switched-mode power supply unit in addition, the ecp-e2 can be controlled remotely by the control input (12), e.g., by means of a plc key commercial data packing unit 1 stk weight per piece (excluding packing) 44.0 g custom tariff number 85363030 country of origin germany technical data general installation instructions when mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor). special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety plc). parallel connection of multiple circuit breakers is not permitted. mounting type on base element color black line (+) so control sc on/off load (+) gnd (-) 2 12 14 13 11 1 control unit i< stop point typ. 1,1 x l 1,8 x l switching time [s] multiples of i n n n 0,01 0,1 1 10 10 2 10 3 10 4 5 1 0 2 3 i k
https://www.phoenixcontact.com/us/products/0900838 08/01/2016???page? 2 ?/? 5 electronic device circuit breaker?-?ecp-e2-8a?-?0900838 technical data general number of positions 1 overvoltage category ii insulating material pa66/6 flammability rating according to ul 94 v0 electrical data fuse electronic fuse type automatic device rated surge voltage 0.5 kv operating voltage 24 v dc 24 v dc () 18 v dc ... 32 v dc nominal current i n 8 a required backup fuse not required, integrated failsafe element dielectric strength max. 32 v dc (load circuit) degree of pollution 2 overvoltage category ii insulating material group i switching capacity i cn active current limitation closed-circuit current range i0 typ. 25 ma 5 ma (when switched on) dimensions height 60 mm width 12.5 mm depth 70 mm height ns 35/7,5 144 mm height ns 35/15 151.5 mm complete module height 115 mm complete module width 38 mm complete module depth 112.5 mm ambient conditions degree of protection ip30 (actuation area) ambient temperature (operation) 0 c ... 50 c (non-condensing) connection data connection method screw connection standards and regulations standards/specifications ul 2367 line (+) so control sc on/off load (+) gnd (-) 2 12 14 13 11 1 control unit i< stop point typ. 1,1 x l 1,8 x l switching time [s] multiples of i n n n 0,01 0,1 1 10 10 2 10 3 10 4 5 1 0 2 3 i k
https://www.phoenixcontact.com/us/products/0900838 08/01/2016???page? 3 ?/? 5 electronic device circuit breaker?-?ecp-e2-8a?-?0900838 technical data standards and regulations ul 508 csa 22.2 no. 14 drawings block diagram diagram classifications ecl@ss ecl@ss 4.0 27141116 ecl@ss 4.1 27141116 ecl@ss 5.0 27141116 ecl@ss 5.1 27141116 ecl@ss 6.0 27141116 ecl@ss 7.0 27141116 ecl@ss 8.0 27141116 ecl@ss 9.0 27141116 etim etim 2.0 ec000899 etim 3.0 ec000899 etim 4.0 ec000899 etim 5.0 ec000899 unspsc unspsc 6.01 30211812 unspsc 7.0901 39121411 line (+) so control sc on/off load (+) gnd (-) 2 12 14 13 11 1 control unit i< stop point typ. 1,1 x l 1,8 x l switching time [s] multiples of i n n n 0,01 0,1 1 10 10 2 10 3 10 4 5 1 0 2 3 i k
https://www.phoenixcontact.com/us/products/0900838 08/01/2016???page? 4 ?/? 5 electronic device circuit breaker?-?ecp-e2-8a?-?0900838 classifications unspsc unspsc 11 39121411 unspsc 12.01 39121411 unspsc 13.2 39121411 approvals approvals approvals ul recognized / eac ex approvals csa approvals submitted approval details ul recognized? eac? accessories accessories marker pen marker pen?-?x-pen 0,35?-?0811228 marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm ? ? terminal marking line (+) so control sc on/off load (+) gnd (-) 2 12 14 13 11 1 control unit i< stop point typ. 1,1 x l 1,8 x l switching time [s] multiples of i n n n 0,01 0,1 1 10 10 2 10 3 10 4 5 1 0 2 3 i k
https://www.phoenixcontact.com/us/products/0900838 08/01/2016???page? 5 ?/? 5 electronic device circuit breaker?-?ecp-e2-8a?-?0900838 accessories zack marker strip?-?zb 6:unbedruckt?-?1051003 zack marker strip, strip, white, unlabeled, can be labeled with: plotter, mounting type: snap into tall marker groove, for terminal block width: 6.2 mm, lettering field: 6.15 x 10.5 mm ? ? zack marker strip?-?zb 6/wh-100:unbedruckt?-?5060935 zack marker strip, strip, white, unlabeled, can be labeled with: plotter, mounting type: snap into tall marker groove, for terminal block width: 6.2 mm, lettering field: 6.15 x 10.5 mm ? ? additional products box mounting base?-?tmcp socket m?-?0916589 modular socket element, 2-position, for holding two circuit breakers, each with a single position ? ? end cover?-?tmcp connect lr?-?0916592 end cover, length:?115 mm, width:?6 mm, color:?black ? ? phoenix contact 2016 ? - all rights reserved http://www.phoenixcontact.com line (+) so control sc on/off load (+) gnd (-) 2 12 14 13 11 1 control unit i< stop point typ. 1,1 x l 1,8 x l switching time [s] multiples of i n n n 0,01 0,1 1 10 10 2 10 3 10 4 5 1 0 2 3 i k


▲Up To Search▲   

 
Price & Availability of 0900838

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X